MOQ: | 1 set |
Standard Packaging: | Wooden Case |
Delivery Period: | 25 days |
Payment Method: | L/C, T/T |
Application :
Synthetic primers can be used for sequencing reactions, SNP sites, polymerase chain reaction (PCR) technology, hybridization and reverse transcription polymerase chain reaction and gene construction, and can also meet ISO and GMP synthesis. Of course, you can go through a different program that can synthesize other primers or longer primers you want.
Technical Specifications:
Product Name
|
HY-192 DNA/RNA Synthesizer
|
Power
|
220V.
|
Working Temperature
|
20C°± 5C°
|
Relative Humidity
|
within 45%
|
Synthetic Scale
|
5nmol-5umol
|
Circulation Time
|
6-8 min
|
Phosphoramidite Bottle Position
|
8-12sets
|
Reagent bottle position
|
7-9 sets
|
Warranty
|
1 year
|
Product Features
1. Each reagent is an independent channel from the liquid storage bottle to the synthesis column without other channels cross.
2. The activator and Phosphoramidite are added sequentially during the coupling process and premixed on the synthesis column to carry out the reaction.
3. It is equipped with two plates with a total of 192 synthesis columns and 12-20 base bottle ports.
4. In addition to 4 standard bases and synthetic auxiliary reagents, there are also 8 modified bases, which can be synthesized as required, such as thiomodification, or other fluorescent modifications and double-labeled TAQMAN probes, etc. More than 8 special bases.
5. It has automatic synthesis and consolidation of bases without the need for pre-mixing of Phosphoramidites.
6. During the whole process of synthesis, there is a certain amount in the synthesis chamber (the amount of gas can be adjusted) The protective gas is filled to prevent air from entering the synthesis cavity and affect the synthesis quality.
7. Reagents and Phosphoramidite can be loaded into two bottles at one time, which can effectively increase the time of single synthesis without frequent replacement of reagents.
8. It is equipped with a cleaning switch valve, and acetonitrile and argon can be used to flush pipelines and valves to avoid blockage of pipelines and valves caused by long-term idling of the equipment.
9. The equipment has self-checking and protection functions, power-off, suspend and continue functions.
10. Working conditions and safety requirements conform to relevant Chinese and international standards or regulations.
Product Photos :
Honya Biotech focuses on DNA/RNA Synthesizer, Dispensing Reaction Integration Workstations, Pipetting and Elution Workstations, Deprotection Equipment, Amidite Dissolved Equipment, Purification Workstation, Synthesis Columns, Phosphoramidites, Modification Amidite, Synthesis Reagents, various consumables, etc, to provide you with the fastest and most efficient DNA/RNA synthesis products and services in the world. We can also customize our instruments to meet customer requirements, making DNA/RNA synthesis faster and more flexible.
We are constantly improving the performance of our products, perfecting our production process and getting the details right. We not only provide you with high quality products, but also provide you with training and service. We are equipped with professional management staff and excellent technical team and maintenance personnel to provide our customers with perfect after-sales service.
Packing & Delivery
1. Are you using synthesis for R&D or production?
Different laboratory settings require varying levels of regulation. Typically, production facilities require specific regulatory documents and services to ensure quality and consistency. Some companies selling DNA RNA oligonucleotide synthesizer only offer instruments and do not offer the necessary documents and services required for production facilities. Services and documents may include Instrument Qualification (IQ), Operational Qualification (OQ), Preventative Maintenance (PM) and more.
MOQ: | 1 set |
Standard Packaging: | Wooden Case |
Delivery Period: | 25 days |
Payment Method: | L/C, T/T |
Application :
Synthetic primers can be used for sequencing reactions, SNP sites, polymerase chain reaction (PCR) technology, hybridization and reverse transcription polymerase chain reaction and gene construction, and can also meet ISO and GMP synthesis. Of course, you can go through a different program that can synthesize other primers or longer primers you want.
Technical Specifications:
Product Name
|
HY-192 DNA/RNA Synthesizer
|
Power
|
220V.
|
Working Temperature
|
20C°± 5C°
|
Relative Humidity
|
within 45%
|
Synthetic Scale
|
5nmol-5umol
|
Circulation Time
|
6-8 min
|
Phosphoramidite Bottle Position
|
8-12sets
|
Reagent bottle position
|
7-9 sets
|
Warranty
|
1 year
|
Product Features
1. Each reagent is an independent channel from the liquid storage bottle to the synthesis column without other channels cross.
2. The activator and Phosphoramidite are added sequentially during the coupling process and premixed on the synthesis column to carry out the reaction.
3. It is equipped with two plates with a total of 192 synthesis columns and 12-20 base bottle ports.
4. In addition to 4 standard bases and synthetic auxiliary reagents, there are also 8 modified bases, which can be synthesized as required, such as thiomodification, or other fluorescent modifications and double-labeled TAQMAN probes, etc. More than 8 special bases.
5. It has automatic synthesis and consolidation of bases without the need for pre-mixing of Phosphoramidites.
6. During the whole process of synthesis, there is a certain amount in the synthesis chamber (the amount of gas can be adjusted) The protective gas is filled to prevent air from entering the synthesis cavity and affect the synthesis quality.
7. Reagents and Phosphoramidite can be loaded into two bottles at one time, which can effectively increase the time of single synthesis without frequent replacement of reagents.
8. It is equipped with a cleaning switch valve, and acetonitrile and argon can be used to flush pipelines and valves to avoid blockage of pipelines and valves caused by long-term idling of the equipment.
9. The equipment has self-checking and protection functions, power-off, suspend and continue functions.
10. Working conditions and safety requirements conform to relevant Chinese and international standards or regulations.
Product Photos :
Honya Biotech focuses on DNA/RNA Synthesizer, Dispensing Reaction Integration Workstations, Pipetting and Elution Workstations, Deprotection Equipment, Amidite Dissolved Equipment, Purification Workstation, Synthesis Columns, Phosphoramidites, Modification Amidite, Synthesis Reagents, various consumables, etc, to provide you with the fastest and most efficient DNA/RNA synthesis products and services in the world. We can also customize our instruments to meet customer requirements, making DNA/RNA synthesis faster and more flexible.
We are constantly improving the performance of our products, perfecting our production process and getting the details right. We not only provide you with high quality products, but also provide you with training and service. We are equipped with professional management staff and excellent technical team and maintenance personnel to provide our customers with perfect after-sales service.
Packing & Delivery
1. Are you using synthesis for R&D or production?
Different laboratory settings require varying levels of regulation. Typically, production facilities require specific regulatory documents and services to ensure quality and consistency. Some companies selling DNA RNA oligonucleotide synthesizer only offer instruments and do not offer the necessary documents and services required for production facilities. Services and documents may include Instrument Qualification (IQ), Operational Qualification (OQ), Preventative Maintenance (PM) and more.