MOQ: | 1set |
Standard Packaging: | It Packed In Wooden Case. |
Payment Method: | L/C, T/T |
Introduction:
Oligonucleotides (or oligos) are usually made up of 13 to 25 nucleotides used in research, genetic testing and forensics. Oligonucleotides have been one of the most important tools in modern molecular biology, The synthesized primers can be used for sequencing reactions, SNP sites, polymerase chain reaction (PCR) technology, hybrid Cross and reverse transcription polymerase chain reaction and gene construction can also satisfy ISO and GMP synthesis. And you can also use different programs to synthesize other primers or longer primers you want.
Sole Strength:
1. Dual Axis motion system:
For traditional synthesis pedestal. There’s one line includes 12 base with long motion length and more space. We updated this technology divided one line into 2 lines. Which saves the synthesis motion time, and saves more space in the box to decrease the synthesis time efficiently.
2. Independent Pipeline System:
For each pipeline of amidite and reagents. We have the independent pipe to avoid pollution interaction between the reagents, the advantage is there’s no dead volume. It also can save the time and cost to clean the pipes by ACN. And each channel can choose the different sequence file and parameter and set Initialization/finalization mode freely. The programme for each pipes can be stored, loaded, inspected and make analysis.
Picture Show:
Specifications:
Channel | 12 | Synthesis Type | DNA/RNA.fluorescent dyes/sulfurizing/Probe |
Mode | Reagent Injection Separately | Period(20 Mer) | 12 primers of 20bp within 2.5h |
Cycled Time | 4-6min | Synthesis Scale | 25nmol-300umol |
Coupling Rate | >99% | Max Length of Primer | 120bp |
Bearing Method | Synthetic column | Wastes | vacuum |
Base/Reagent Pouring Mode | reagent injection separately | Base/Reagent Drive Way | press out by protected gas |
Amidite Position Base | 16pcs | Reagent Position Base | 9 pcs |
Reagent Cylinder Configuration | single position standard. double optional | Reagent Bottle Size |
450ml/4L Customization |
Synthesis Merger Base | Automatic merge the base | Data Import Method | Import the sequence automatically by Excel |
Gas needed | Nitrogen or Argon | Color | Pure White |
Reagent Pipe Dimension | OD1/8' and ID/16' | Base Pipe Dimension | OD1/16, ID0.8mm |
Outsize | 1100*710*890mm | Package Size | 1200*810*1000mm |
Working Environment | 25℃±4℃ | Relative humidity | ≤45% |
Power | Single Phase/220V | Gas needed | Nitrogen or Argon |
Technical Advantages:
1 | lightweight and modular design | which is designed easy to add or removing modules. And optimize the configuration in future. |
2 | Compact design | which using an embedded control computer, no more space for computer, shortening half of the length than other similar synthesizer |
3 | Graphical operation mode | In the testing phase and the initial stage of synthesis, the pipeline can be tested automatically, the status of liquids, pipelines, valves, etc. |
4 | Larger synthesis scale | dual-axis motion system reduced the length of the column support plate ,also saves a lot of space to put larger scale columns. And it can synthesize 12 primers at the same time, which is twice as large as the traditional synthesizer |
5 | AMI/MODIFY can be flexibly configured | Base amidite and modified amidite can be set freely, and you can choose different Synthesis programme |
6 | OXI/SUL can be configured separately | OXI and SUL can be configured separately. |
7 | Independent programme of each channel | Each channel can select different sequence files and process parameters, which can set the initial synthesis position of the sequence and Initialization/finalization mode respectively, etc. For each channels programme can be saved, loaded, tested, and statistically analyzed. |
8 | Real-time display of the synthesis process | During the synthesis process, it can be paused manually or automatically, and then the operate the amidite and other reagent. |
MOQ: | 1set |
Standard Packaging: | It Packed In Wooden Case. |
Payment Method: | L/C, T/T |
Introduction:
Oligonucleotides (or oligos) are usually made up of 13 to 25 nucleotides used in research, genetic testing and forensics. Oligonucleotides have been one of the most important tools in modern molecular biology, The synthesized primers can be used for sequencing reactions, SNP sites, polymerase chain reaction (PCR) technology, hybrid Cross and reverse transcription polymerase chain reaction and gene construction can also satisfy ISO and GMP synthesis. And you can also use different programs to synthesize other primers or longer primers you want.
Sole Strength:
1. Dual Axis motion system:
For traditional synthesis pedestal. There’s one line includes 12 base with long motion length and more space. We updated this technology divided one line into 2 lines. Which saves the synthesis motion time, and saves more space in the box to decrease the synthesis time efficiently.
2. Independent Pipeline System:
For each pipeline of amidite and reagents. We have the independent pipe to avoid pollution interaction between the reagents, the advantage is there’s no dead volume. It also can save the time and cost to clean the pipes by ACN. And each channel can choose the different sequence file and parameter and set Initialization/finalization mode freely. The programme for each pipes can be stored, loaded, inspected and make analysis.
Picture Show:
Specifications:
Channel | 12 | Synthesis Type | DNA/RNA.fluorescent dyes/sulfurizing/Probe |
Mode | Reagent Injection Separately | Period(20 Mer) | 12 primers of 20bp within 2.5h |
Cycled Time | 4-6min | Synthesis Scale | 25nmol-300umol |
Coupling Rate | >99% | Max Length of Primer | 120bp |
Bearing Method | Synthetic column | Wastes | vacuum |
Base/Reagent Pouring Mode | reagent injection separately | Base/Reagent Drive Way | press out by protected gas |
Amidite Position Base | 16pcs | Reagent Position Base | 9 pcs |
Reagent Cylinder Configuration | single position standard. double optional | Reagent Bottle Size |
450ml/4L Customization |
Synthesis Merger Base | Automatic merge the base | Data Import Method | Import the sequence automatically by Excel |
Gas needed | Nitrogen or Argon | Color | Pure White |
Reagent Pipe Dimension | OD1/8' and ID/16' | Base Pipe Dimension | OD1/16, ID0.8mm |
Outsize | 1100*710*890mm | Package Size | 1200*810*1000mm |
Working Environment | 25℃±4℃ | Relative humidity | ≤45% |
Power | Single Phase/220V | Gas needed | Nitrogen or Argon |
Technical Advantages:
1 | lightweight and modular design | which is designed easy to add or removing modules. And optimize the configuration in future. |
2 | Compact design | which using an embedded control computer, no more space for computer, shortening half of the length than other similar synthesizer |
3 | Graphical operation mode | In the testing phase and the initial stage of synthesis, the pipeline can be tested automatically, the status of liquids, pipelines, valves, etc. |
4 | Larger synthesis scale | dual-axis motion system reduced the length of the column support plate ,also saves a lot of space to put larger scale columns. And it can synthesize 12 primers at the same time, which is twice as large as the traditional synthesizer |
5 | AMI/MODIFY can be flexibly configured | Base amidite and modified amidite can be set freely, and you can choose different Synthesis programme |
6 | OXI/SUL can be configured separately | OXI and SUL can be configured separately. |
7 | Independent programme of each channel | Each channel can select different sequence files and process parameters, which can set the initial synthesis position of the sequence and Initialization/finalization mode respectively, etc. For each channels programme can be saved, loaded, tested, and statistically analyzed. |
8 | Real-time display of the synthesis process | During the synthesis process, it can be paused manually or automatically, and then the operate the amidite and other reagent. |