Standard Packaging: | Woodencase |
Customized Support and 220V Power Supply for Modified RNAs siRNA Synthesis Instrument
About Oligo Synthesizer with 12 Channels,
Independent Synthesis Channels: The synthesizer is equipped with twelve fully independent synthesis channels, allowing for parallel synthesis of twelve unique oligonucleotide sequences, thus enhancing productivity and throughput.
Channel Design: Each channel includes a separate reaction vessel or column for solid-phase synthesis, ensuring no cross-contamination between individual synthesis reactions.
Nucleotide Loading Capacity: Capable of loading varying amounts of phosphoramidite or other chemistries for the synthesis of oligos ranging from 5 to 200 bases or more.
Automated Reagent Delivery System: Precision pumps deliver controlled volumes of reagents such as activators, coupling agents, capping agents, and oxidizers to each channel according to programmed protocols.
Temperature Control: Independent temperature control within each synthesis channel for optimized coupling and detritylation reactions.
Software Interface: An advanced software platform enables sequence input, automated protocol generation, and real-time monitoring of synthesis progress, including UV monitoring for quantitation.
Customizable Chemistry: Supports custom synthesis using a wide range of chemistries, including standard and modified nucleotides, to accommodate various research needs.
Post-Synthesis Processing: Built-in or optional modules for cleavage and deprotection procedures, followed by purification methods such as precipitation, desalting, or HPLC.
Washing Efficiency: Intermittent and thorough washing steps in each channel to remove unreacted reagents and improve product purity.
Process Optimization: Flexible programming to allow for adjustments to coupling times, detritylation cycles, and other parameters to optimize yield and purity for different sequences.
Safety Features: Includes safety mechanisms such as automatic shutoffs, ventilation systems compatible with chemical hoods, and proper waste management to ensure safe operation.
Data Management: Provides comprehensive data logging and export functions for traceability and documentation purposes.
Specification:
Synthetic primers can be used for sequencing reactions, SNP sites, polymerase chain reaction (PCR) technology, hybridization and reverse transcription polymerase chain reaction and gene construction, and can also meet ISO and GMP synthesis. Of course, you can go through a different program that can synthesize other primers or longer primers you want.
Single channel synthesis scale |
5nmol-1umole. |
Synthesis cycle time |
up to 6-8 minutes |
Synthesis cycle (20mer) |
2-3 hours |
Phosphoramidite bottle base |
8 sets |
Reagent bottle base |
7 sets |
Base bottle |
60/240/480ml screw mouth universal reagent bottle interface |
Auxiliary reagent bottle |
GL38 bottle mouth, use for universal 4L reagent bottles . |
Reagent driving method |
protective gas down pressure type |
Waste liquid discharge |
positive pressure |
Coupling rate |
99% |
The maximum length |
exceeds 120mer |
Power supply |
Single-phase 220V. |
Working temperature |
20C°± 5C° |
Relative humidity |
within 40%. |
Persistence of the operation |
It can operate normally and continuously. |
Photo Show:
Specifications:
1. Each reagent is an independent channel from the liquid storage bottle to the synthesis column without other channels cross.
2. The activator and Phosphoramidite are added sequentially during the coupling process and premixed on the synthesis column to carry out the reaction.
3. It is equipped with two plates with a total of 192 synthesis columns and 12-20 base bottle ports.
4. In addition to 4 standard bases and synthetic auxiliary reagents, there are also 8 modified bases, which can be synthesized as required, such as thiomodification, or other fluorescent modifications and double-labeled TAQMAN probes, etc. More than 8 special bases.
5. It has automatic synthesis and consolidation of bases without the need for pre-mixing of Phosphoramidites.
6. During the whole process of synthesis, there is a certain amount in the synthesis chamber (the amount of gas can be adjusted) The protective gas is filled to prevent air from entering the synthesis cavity and affect the synthesis quality.
7. Reagents and Phosphoramidite can be loaded into two bottles at one time, which can effectively increase the time of single synthesis without frequent replacement of reagents.
8. It is equipped with a cleaning switch valve, and acetonitrile and argon can be used to flush pipelines and valves to avoid blockage of pipelines and valves caused by long-term idling of the equipment.
9. The equipment has self-checking and protection functions, power-off, suspend and continue functions.
Company Profile:
Hunan Honya Biotech Co,.Ltd. which was established by the master of molecular Biology. We have more than Ten years of working experience in the DNA filed, our company focuses on DNA/RNA synthesis instrument, but also synthesis use reagents, consumables, Phosphonamidites, to provide you with the fastest and most efficient DNA/RNA synthesis products.
We have experienced synthetic technical service engineers, not only to provide you with quality products, but also to provide you with synthetic related training and services. The main products of the company include: DNA/RNA Synthesizer, Deprotection Instrument, Elution Instrument, Purification Instrument, Amidites Dissolved Instrument, Synthesis Column of various specifications, Modified Amidite, Synthetic Reagents, other consumables and so on.
Standard Packaging: | Woodencase |
Customized Support and 220V Power Supply for Modified RNAs siRNA Synthesis Instrument
About Oligo Synthesizer with 12 Channels,
Independent Synthesis Channels: The synthesizer is equipped with twelve fully independent synthesis channels, allowing for parallel synthesis of twelve unique oligonucleotide sequences, thus enhancing productivity and throughput.
Channel Design: Each channel includes a separate reaction vessel or column for solid-phase synthesis, ensuring no cross-contamination between individual synthesis reactions.
Nucleotide Loading Capacity: Capable of loading varying amounts of phosphoramidite or other chemistries for the synthesis of oligos ranging from 5 to 200 bases or more.
Automated Reagent Delivery System: Precision pumps deliver controlled volumes of reagents such as activators, coupling agents, capping agents, and oxidizers to each channel according to programmed protocols.
Temperature Control: Independent temperature control within each synthesis channel for optimized coupling and detritylation reactions.
Software Interface: An advanced software platform enables sequence input, automated protocol generation, and real-time monitoring of synthesis progress, including UV monitoring for quantitation.
Customizable Chemistry: Supports custom synthesis using a wide range of chemistries, including standard and modified nucleotides, to accommodate various research needs.
Post-Synthesis Processing: Built-in or optional modules for cleavage and deprotection procedures, followed by purification methods such as precipitation, desalting, or HPLC.
Washing Efficiency: Intermittent and thorough washing steps in each channel to remove unreacted reagents and improve product purity.
Process Optimization: Flexible programming to allow for adjustments to coupling times, detritylation cycles, and other parameters to optimize yield and purity for different sequences.
Safety Features: Includes safety mechanisms such as automatic shutoffs, ventilation systems compatible with chemical hoods, and proper waste management to ensure safe operation.
Data Management: Provides comprehensive data logging and export functions for traceability and documentation purposes.
Specification:
Synthetic primers can be used for sequencing reactions, SNP sites, polymerase chain reaction (PCR) technology, hybridization and reverse transcription polymerase chain reaction and gene construction, and can also meet ISO and GMP synthesis. Of course, you can go through a different program that can synthesize other primers or longer primers you want.
Single channel synthesis scale |
5nmol-1umole. |
Synthesis cycle time |
up to 6-8 minutes |
Synthesis cycle (20mer) |
2-3 hours |
Phosphoramidite bottle base |
8 sets |
Reagent bottle base |
7 sets |
Base bottle |
60/240/480ml screw mouth universal reagent bottle interface |
Auxiliary reagent bottle |
GL38 bottle mouth, use for universal 4L reagent bottles . |
Reagent driving method |
protective gas down pressure type |
Waste liquid discharge |
positive pressure |
Coupling rate |
99% |
The maximum length |
exceeds 120mer |
Power supply |
Single-phase 220V. |
Working temperature |
20C°± 5C° |
Relative humidity |
within 40%. |
Persistence of the operation |
It can operate normally and continuously. |
Photo Show:
Specifications:
1. Each reagent is an independent channel from the liquid storage bottle to the synthesis column without other channels cross.
2. The activator and Phosphoramidite are added sequentially during the coupling process and premixed on the synthesis column to carry out the reaction.
3. It is equipped with two plates with a total of 192 synthesis columns and 12-20 base bottle ports.
4. In addition to 4 standard bases and synthetic auxiliary reagents, there are also 8 modified bases, which can be synthesized as required, such as thiomodification, or other fluorescent modifications and double-labeled TAQMAN probes, etc. More than 8 special bases.
5. It has automatic synthesis and consolidation of bases without the need for pre-mixing of Phosphoramidites.
6. During the whole process of synthesis, there is a certain amount in the synthesis chamber (the amount of gas can be adjusted) The protective gas is filled to prevent air from entering the synthesis cavity and affect the synthesis quality.
7. Reagents and Phosphoramidite can be loaded into two bottles at one time, which can effectively increase the time of single synthesis without frequent replacement of reagents.
8. It is equipped with a cleaning switch valve, and acetonitrile and argon can be used to flush pipelines and valves to avoid blockage of pipelines and valves caused by long-term idling of the equipment.
9. The equipment has self-checking and protection functions, power-off, suspend and continue functions.
Company Profile:
Hunan Honya Biotech Co,.Ltd. which was established by the master of molecular Biology. We have more than Ten years of working experience in the DNA filed, our company focuses on DNA/RNA synthesis instrument, but also synthesis use reagents, consumables, Phosphonamidites, to provide you with the fastest and most efficient DNA/RNA synthesis products.
We have experienced synthetic technical service engineers, not only to provide you with quality products, but also to provide you with synthetic related training and services. The main products of the company include: DNA/RNA Synthesizer, Deprotection Instrument, Elution Instrument, Purification Instrument, Amidites Dissolved Instrument, Synthesis Column of various specifications, Modified Amidite, Synthetic Reagents, other consumables and so on.